CONTEC ECG80A HANDHELD ECG MONITOR WITH PRINTER, REUSABLE ELECTRODS-USA SELLER Sold by: EastShore Medical Supply In Stock: 1. $337.95 USDAdd To Cart. ABOUT CONTEC MEDICAL SYSTEMS CO.,LTD. Contec Medical Systems focusing on research,manufacture and distribution of medical instruments,was founded in 1992 as a high-tech company. At present there are more than 1200 employees in our company. Our product line covers a wide range of 13 categories.Most of the domestic hospitals are our customers. View & download of more than 546 Contec PDF user manuals, service manuals, operating guides. I/O Systems, Pci Card user manuals, operating guides & specifications.
Introductions
This product is single channel,12 leads electrocardiograph, can be widely applied in ECG check-up under different circumstances such as in family ,hospital consultation, doctor's diagnosis, physical check-up,social medical organizations etc. it can implement real time continuous records of clear and exact single-channel ECG waveform using thermo sensitive printer at the same time. waveforms also can be freezed at any time. it has manual and automatic modes to be chosen and Chinese/English operation interface,it is easy to be used.
Features
■2.7' FSTN display shows the working status and ECG waveform. Check the waveform before printing to save record paper.
■Output system:High-resolution thermal-array(8dots/mm),it needs not be adjusted.Recording frequency Response:Up to 150Hz.
■The device can record exact single ECG waveform and remark. The mark includes:lead sign,ensitivity,paper speed,filter state.
■Under automatic mode,just press the button once,it starts record procedure,which can enhance your work efficiency
■The language of operation interface include( Chinese,English,French,Italian,Turkish,Espanol,Deutsch,Russia)
■The keyboard's control is whole touch type,it's convenient to operate.
■Classification:IEC class I,type CF defibrillator proof
■This instrument can record 160 pieces of ECG waveform and 4 hours continually under the best DC state
■The figure of whole device is elegancy and gliding
■According to defendence degree of deleterious fluid, this device is belong to common device.
■Digital signal processor for effective inhibition of AC,EMG and DFT,receive the better ECG waveform.
■According to the working mode class, this device belongs to continuous operation equipment.
Technical Specification
■Normal work environment
Running
Environment temperature: +5℃~+35℃
Relative humidity: ≤80%
Atmospheric pressure: 86kPa~106kPa
Store and Transportation
Environment temperature: -10~55℃
Relative humidity: ≤95%
Atmospheric pressure: 50kPa~106kPa
■Input way: Floating and defibrilation protection
■Lead: Standard 12 leads
■Patient leak current: <10μA
■Sampling rate:1000Hz
■A/D change:10 Bit
■Frequency response: 0.05Hz~150Hz
■Time constant: Time constant>3.2s
■CMRR: >60dB, >100dB( With AC filter)
■Enduring polarization voltage:±500mV
■Noise level: ≤15μVp-p
■EMG interference filter: 35Hz(-3dB)
■AC filter:50Hz/60Hz(≥20dB)
■Sensitivity choice: 5,10,20mm/mV, error:±5%.Standard sensitivity is 10mm/mV±0.2mm/mV
■Recording way: Thermal printing system
■Auto-record: according the the record format and auto-mode to set, auto leads-changing, auto measurement.
■Manual record: according the record format to record, manual leads-changing.
■Specification of recording paper:50mm(W) × 20mm(L)High-speed thermal paper
■Paper speed: 25mm/s,50mm/s,error:±5%
■Product safety type:IEC class I,type CF defibrillator proof
■Size:190mm(L)*90mm(W)*40mm(H)
■Net Weight:0.45kg
■Power supply
Input: AC: 100-240V, 50/60Hz
Output: DC: 9V
DC: 7.4V, Lithium rechargeable battery
Accessories
ECG leads 1 set
Limb electrode clamp 1 set
Chest electrode 1 set
Power connection 1 piece
Recording paper 1 piece
Power adapters 1 piece
User manual 1 piece
Option:
ECG80A software, connect with the PC by USB , collect real-time data to the software to analyze and print the report,
Certification
CE, CCC, FDA
ECG Machines
Code – ECG300G/INT
Description – ECG 300G – 3 Channel & Interpretation
Features | * High resolution thermal printing system, high precision * 12 leads collection in phase as well as 3 leads printing in phase * Digital design and filter, baseline auto-adjustable * LCD displays operation menu * DC/AC auto-exchange * Automatic measurement, analysis and diagnosis with high speed * Elegant and compact outlook, with inner handhold |
Specifications | |
Model | ECG 300G |
ECG Input Circuit | Floating; protection against defibrillator effect. |
Lead | Standard 12 leads |
Patient Current Leakage | 10µA |
Sampling Rate | 1000Hz |
A/D conversion | 12 bit |
Frequency Response | 0.05Hz~150Hz (-3dB + 0.4dB) |
Time constant: | >3.2 seconds |
CMRR | >60dB >100dB (Add Filter) |
Enduring polarization voltage | ±500mV |
Noise Level | <15µVp-p |
Measurement parameters EMG Interference filter | 25Hz/35Hz (-3dB) |
AC filter | 50Hz/60Hz (≥20dB) |
Recording way | Thermal printing system (32spots/mm) |
Recording paper | 80mm(W) x 20mm (L) |
Sensitivity choice | 5,10,20,40mm/mV, Auto |
Wave Output Auto-Record Rhythm Record Manual record | 25mm/s, 50mm/s 25mm/s, 50mm/s 5mm/s, 6.25mm/s, 10mm/s, 12.5mm/s, 25mm/s, 50mm/s |
AC DC | 220V, 50Hz (110V, 60Hz) 7.4V, 3700mAh rechargeable lithium polymer battery |
Fuse specification | 2pcs Ø 5 x 20mm AC Time lag: T250mA/250V (Power Supply 220V) |
Product safety Type | Class I, type CF applied part, which has defibrillation – proof applied part |
Fuse Specification | 2 pcs Ø5 x 20mm AC time lag: T250mA/250V (power supply: 220V) |
Dimensions | 315mm (L) x 215mm (W) x 77mm (H) |
Net Weight | 2.25kg |
Code – ECG600G/INT
Description – ECG 600G – 3/6 Channel & Interpretation
How to download matlabwesternagents.
Features | * 1.7″ TFT, touch screen, LED backlight * Digital isolation technology and signal PRO-cessing solution, digital filter * Patient management, name and age and ID * Detail analysis report * Multi-language options: Germany, France, Italian, Turkey, etc * Built-in lithium rechargeable battery, wide thermal printing system * USB and LAN socket. Memory: Built-in memory or mini SD Memory card. Store more than 1000 pieces of archive * Auto-measurement, auto-analysis, and auto-interpretation |
Specifications | |
Model | ECG 600G |
Product safety Type | Class I, type CF applied part, which has defibrillation – proof applied part |
Leads | Standard 12 Leads |
Input | Floating; protection against defibrillator effect. |
Input impedance | ≥ 50M |
Patient Leak Current | <10uA |
Sampling Rate | 1000Hz |
Frequency Response | 0.05 ~ 150Hz (-3dB) |
Time Constants | >3.2s |
CMRR | >100dB |
Dimension of Recording Paper | 80mm x 20M |
Paper Speed | 25mm/s, 50mm/s |
Sensitivity choice | 5,10,20mm/mV |
Measurement parameters | HR, R-R interval, P-Duration, QRS Duration, Q-T interval, T-Tc, P Axis, QRS Axis, T Axis, R(V5), S (V1), R(V5) + S(V1) |
Product Safety Type | Class I, CF. Defibrillation and pacing protection |
Enduring Polarization voltage | ± 300mv |
Noise Level | <15uVp-p |
Dimension | 130mm (L) x 74mm (W) x 25mm (H) |
Net Weight | 2.3kg |
Code – ECG1200G/INT
Description – ECG 1200G – 12 Channel & Interpretation
Code – ECG300G/INT
Description – ECG 300G – 3 Channel & Interpretation
Features | * High resolution thermal printing system, high precision * 12 leads collection in phase as well as 3 leads printing in phase * Digital design and filter, baseline auto-adjustable * LCD displays operation menu * DC/AC auto-exchange * Automatic measurement, analysis and diagnosis with high speed * Elegant and compact outlook, with inner handhold |
Specifications | |
Model | ECG 300G |
ECG Input Circuit | Floating; protection against defibrillator effect. |
Lead | Standard 12 leads |
Patient Current Leakage | 10µA |
Sampling Rate | 1000Hz |
A/D conversion | 12 bit |
Frequency Response | 0.05Hz~150Hz (-3dB + 0.4dB) |
Time constant: | >3.2 seconds |
CMRR | >60dB >100dB (Add Filter) |
Enduring polarization voltage | ±500mV |
Noise Level | <15µVp-p |
Measurement parameters EMG Interference filter | 25Hz/35Hz (-3dB) |
AC filter | 50Hz/60Hz (≥20dB) |
Recording way | Thermal printing system (32spots/mm) |
Recording paper | 80mm(W) x 20mm (L) |
Sensitivity choice | 5,10,20,40mm/mV, Auto |
Wave Output Auto-Record Rhythm Record Manual record | 25mm/s, 50mm/s 25mm/s, 50mm/s 5mm/s, 6.25mm/s, 10mm/s, 12.5mm/s, 25mm/s, 50mm/s |
AC DC | 220V, 50Hz (110V, 60Hz) 7.4V, 3700mAh rechargeable lithium polymer battery |
Fuse specification | 2pcs Ø 5 x 20mm AC Time lag: T250mA/250V (Power Supply 220V) |
Product safety Type | Class I, type CF applied part, which has defibrillation – proof applied part |
Fuse Specification | 2 pcs Ø5 x 20mm AC time lag: T250mA/250V (power supply: 220V) |
Dimensions | 315mm (L) x 215mm (W) x 77mm (H) |
Net Weight | 2.25kg |
Code – ECG600G/INT
Description – ECG 600G – 3/6 Channel & Interpretation
How to download matlabwesternagents.
Features | * 1.7″ TFT, touch screen, LED backlight * Digital isolation technology and signal PRO-cessing solution, digital filter * Patient management, name and age and ID * Detail analysis report * Multi-language options: Germany, France, Italian, Turkey, etc * Built-in lithium rechargeable battery, wide thermal printing system * USB and LAN socket. Memory: Built-in memory or mini SD Memory card. Store more than 1000 pieces of archive * Auto-measurement, auto-analysis, and auto-interpretation |
Specifications | |
Model | ECG 600G |
Product safety Type | Class I, type CF applied part, which has defibrillation – proof applied part |
Leads | Standard 12 Leads |
Input | Floating; protection against defibrillator effect. |
Input impedance | ≥ 50M |
Patient Leak Current | <10uA |
Sampling Rate | 1000Hz |
Frequency Response | 0.05 ~ 150Hz (-3dB) |
Time Constants | >3.2s |
CMRR | >100dB |
Dimension of Recording Paper | 80mm x 20M |
Paper Speed | 25mm/s, 50mm/s |
Sensitivity choice | 5,10,20mm/mV |
Measurement parameters | HR, R-R interval, P-Duration, QRS Duration, Q-T interval, T-Tc, P Axis, QRS Axis, T Axis, R(V5), S (V1), R(V5) + S(V1) |
Product Safety Type | Class I, CF. Defibrillation and pacing protection |
Enduring Polarization voltage | ± 300mv |
Noise Level | <15uVp-p |
Dimension | 130mm (L) x 74mm (W) x 25mm (H) |
Net Weight | 2.3kg |
Code – ECG1200G/INT
Description – ECG 1200G – 12 Channel & Interpretation
Features | * ECG1200G 12-channel ECG, gathers 12-lead ECG signals simultaneously and prints out the ECG waveforms with thermal printing system * Uses are mainly in Hospitals, Clinics (medical establishments) * 800 x 600 dots high resolution colour LCD * Convenient and quick button setup * Automatic/manual mode to record and display ECG waveform * Auto-measure of ECG waveform parameter * Multiple switchable interface language |
Specifications | |
Model | ECG 1200G |
Input Circuit | Floating; protection against defibrillator effect. |
Lead | Standard 12 leads |
Display | 8' TFT Display, 800 x 600 pixels, LED backlight |
Patient Current Leakage | 10µA |
Frequency response | 0.05Hz – 150Hz (-3dB) |
Input Impedance | 50MΩ |
Time Constant | >3.2seconds |
CMRR | >60dB, ≥100dB (Adding Filter) |
EMG Interference filter | 35Hz (-3dB) |
Recording | Thermal Printing System |
Specification of recording paper | 210mm (W) x 20mm (H) high speed paper |
Paper speed | Auto record: 25mm/s, 50mm/s, error ± 5% Rhythm record: 25mm/s, 50mm/s, error ± 5% Manual record: 5mm/s, 6.25mm/s, 10mm/s, 12.5mm/s, 25mm/s, 50mm/s, error ± 5% |
Sensitivity selections | 5,10,20,40mm/mV, error± 5%. Standard sensitivity is 10mm/mV±0.2mm/mV |
Auto Record | Record setup according to auto record format and mode, automatically changing leads, measuring and analysing |
Rhythm Record | Record setup according to rhythm record format and mode, automatically measuring and analysing |
Manual Record | Record setup according to manual record format, manually changing leads |
Measurement parameters | HR, P-R interval, P Duration, QRS Duration, T Duration, Q-T interval, Q-Tc P axis, QRS Axis, T Axis R(V5), S(V1), R(V5) + S(V1) |
Product Safety Type | Class I CF applied part, there is defibrillation and pacing protection circuit in it |
Enduring Polarization voltage | ±500mV |
Power Supply AC | AC:100-240V, 50/60Hz DC: 14,8V, 3700mAh rechargeable lithium battery |
Noise Level | <15µVp-p |
Size | 334mm(L) x 320mm (W) x 85mm (H) |
Code – ECG1103B
Description – ECG – Digital 3 Channel – 12 Lead – ECG1103B with interpretation
Features | * Simultaneously acquisition of 12-lead ECG data, IEC Class I, type CF safety standard * Selectable four modes of leads: Manual (standard single channel), Auto I (standard three channel), Auto II (standard single channel plus any rhythm lead) and Auto III (European three channel) * Function of ECG parameters measurement and distinguish point printing under automatic mode * LCD display of operation menu, ECG waveform, AMP menu and parameter setting * Powerful filter for AC, EMG and DFT interference * High resolution thermal printer * AC and DC power supply, rechargeable built-in battery, at least 2 hours' working time * High resolution and multiple print formats ensure best print quality of ECG waveforms * Capability of the input & output for analogue signal * Optional : USB interface, net-working capacity |
Specifications | |
Model | ECG 1103B |
Input Circuit | Floating; protection against defibrillator effect. |
Lead | Standard 10 leads, European leads |
Patient Current Leakage | < 10mA |
Input Impedance | 50Ω |
Calibrating Voltage | 1mV ±3% |
Digital Sampling | 10 bits (simultaneously acquisition of 10 leads ECG data) |
Frequency Response | 0.05Hz~150Hz (-3dB) |
Time Constant | >3.2seconds |
CMRR | >100dB (with filter) |
EMG Filter | 40Hz (-3dB) |
DFT Filter | Automatic Adjustment |
Sensitivity | 5, 10, 20mm/mV ±3% |
Recording System | Thermal-array |
Paper Speed | 25, 50mm/s ±3% |
Recording Paper | 50/63mm, 20m, high-speed roll |
Input Circuit Current | 50nA |
Safety Standard | IEC class I, type CF |
Power Supply AC | 220V / 110V, 50/60Hz |
Power Supply DC | 14.4V rechargeable battery |
Depolarization Voltage | ±300mV |
Noise Level | <15µVp-p |
Dimensions | 300mm x 230mm x 65mm |
Net Weight | 2.75 Kgs |
Gross Weight | 4.50 Kgs |
Code – ECG1103G/INT
Description – ECG 1103G – 3 Channel & Interpretation
Features | * Light in weight, compact in size * Three kinds of operation mode: Automatic, Manual, Analysis * Standard lead mode or European lead mode available * Automatic measurement and interpretation * Detection and alarm of Lead-off, no paper, no battery * Built-in ECG simulator * Built-in rechargeable lithium battery with high capacity * Automatic adjustment of baseline for optimal recording * RS232 communication interface in standard configuration for connecting with special network, PC or Setting up of ECG database, option Blue Tooth interface * Built-in help function: electrode positioning, ECG basic knowledge, common trouble-shooting, etc. (not available in Class B machine) * Clinical information such as patient ID, name, sex, age, height, weight, drugs and hospital name can be input * Case storage function: 15 cases can be saved in the machine or as much as 150 cases in a SD card. Saved ECG waveforms can be cine-looped, printed out or transferred to PC (not available in Class B machine) |
Code – ECG1103W
Description – ECG 1103L – 3 Channel Large screen
Contec Ecg80a User Manual User
Features | * Light in weight, compact in size * Operation Mode: Automatic, Manual, Analysis * Standard lead mode of European/Cabera lead mode available * Automatic Measurement and Interpretation * Detection and alarm of Lead-off, No Paper, No Battery * Built-in ECG simulator * Built-in rechargeable lithium battery with high capacity * Automatic adjustment of baseline for optimal recording * RS232 communication interface in standard configuration for connecting with PC or setting up of ECG database, option USB and Blue Tooth interface * Built-in Help Function: electrode positioning, ECG basic knowledge, common trouble-shooting, etc. (not available in Class B ECG) * Clinical information such as patient ID, name, sex, age, height, weight, drugs and hospital name can be input * Case Storage function: 15 cases can be saved in the machine or as much as 150 cases in a SD card. Saved ECG waveforms can be cine-looped, printed out or transferred to PC (not available in Class B ECG) |
Specifications | |
Model | ECG 1103L |
Input Circuit | Floating, protection against defibrillator and pacemaker |
Input Circuit Current | ≤50nA. |
Input Impedance | 50MΩ |
Display | 5.7' Screen Display |
A/D Converter | 18 bit |
Acquisition Mode | 12 leads acquisition simultaneously |
Patient Current Leakage | 10µA |
Time Constant | ≥3.2seconds |
Frequency Response | 0.05Hz~150Hz |
Sensitivity | 2.5, 5,10, 20(mm/mV) Auto |
CMRR | >100dB (with AC filter) |
Calibration Voltage | 1mV±2% |
Noise Level | <15µVp-p |
Anti-Baseline Drift | Automatic |
Filter | EMG Filter: 35Hz~45Hz (-3dB)45Hz (-3dB) ADS Filter: Auto (0.15-0.50Hz) HUM Filter: 50Hz/60Hz (-20dB) |
Patient Current Leakage | <10µA |
Paper Speed | 6.25/12.5/25/50mm/s |
Recording Paper | 50mm (width), 20/30m (length), roll/Z-fold |
Power Supply | AC: 110/220V, 50/60Hz, 85V~265V (option) DC: 14.4V, built-in rechargeable lithium battery |
Dimension | 345mm x 300mm x 80mm; 400mm x 180mm x 355mm (Carton) |
Net Weight | 2.5kgs |
Gross Weight | 4.5kgs |
Code – ECG1103VET
Description – ECG 1103 vet
Code – ECG1112/INT
Description – ECG 1112 – 12 Channel & Interpretation
Features | * Simultaneous acquisition of 12-lead ECG data, real-time recording and printing of 12-channel ECG waveform * Graphic display of 12-lead ECG waveform * Built-in analysis software of age which assures accurate analysis result * Auto-measurement, auto-interpretation, waveform playback and storage of ECG data * RS232 and USB interface cope with> |
Specifications | |
Model | ECG 1112L |
Screen Size | 5.7 inch |
Input Circuit | Floating, protection against defibrillator and pacemaker |
Leads | Standard 12 Lead |
Input Impedance | >50MΩ |
Imput Circuit Current | <50n A |
Patient Current Leakage | <10µ A |
Calibration Voltage | 1mV ± 2% |
Depolarization Voltage | ±500mV |
Ampling Rate | 1.0ms (1000Hz) |
A/D Converter | 12 bits |
Frequency Response | 0.05Hz-165Hz (-3dB) |
Time Constant | >3.2s |
Noise Level | <15µVp-p |
CMRR | >100dB |
Digital Filters | HUM, EMG, ADS |
Sensitivity | Auto, 2.5,5,10,20mm/mV (± 2%) |
Measurement | Heart rate, PR Int., Vent. Rate, P/QPS/T Axis |
Patient Data | Data, time, ID, name, gender, age, height, weight, blood pressure. etc |
System Data | Sensitivity, paper speed, filter on/off, hospital name, etc |
Print-out | Waveform, waveform + measurement report, or waveform + measurement report + analysis report |
Printing System | High speed, high sensitivity thermal matrix printing system |
Paper Speed | 6.25,12.5, 25, 50mm/s (± 3%) |
Printing Paper | 216mm x 30m roll paper |
Power Supply AC: DC: BATTERY: | 100V-240V (50/60Hz) 19V/3.5A 14.4V/4400mAh, built-in rechargeable lithium battery, over 2 hours working time |
Safety Standard | IEC, Class I, Type CF |
Carton Size | 415 x 195 x 380mm |
Weight | 5.5kgs |
Optional Accessories | SD Card Carrying Bag PCECG-500A work station software |
Code – ECG-C10LBCW
Description – ECG Cable – 10 Lead + Button Carewell
Code – ECGC2000
Description – ECG Cardiocare 2000
Contec Ecg80a User Manual Instructions
Features | * Simultaneous 12 Channel resting ECG * ECG interpretation program * A4 size various printout formats * Fax transmission function * ECG filing system 'EKGPlus' * Continuous software upgrade |
Specifications | |
Model | Cardiocare2000 |
ECG Leads | 12 leads simultaneous 10 second resting ECG |
Dimension | 296(W) x 305.5(H) x 92.5(D)mm Approx. 2.98Kg |
Recording Channel | 3,6,12 channel (60 sec) |
Sensitivity | 5,10,12 channel and 1 channel (60 sec) |
Printing speed | 12.5 25, 50mm/s |
Filters | AC (50/60Hz) |
Display | 2 X 16 character LCD display |
LCD display LED indicator | Sensitivity, speed, filter status, HR, printing form, rhythm Lead signal quality, power source, battery |
Keyboard | Membrane keyboard Alphanumeric and symbol available |
Patient Data | ID, name, age, sex, height, weight |
Basic Measurements | Heart rate, PR, QRS, QT/QTc, P-R-T axis |
Recorder | Thermal print head, thermal roll paper Report papers: - Width: A4: 210mm or 8.5' - Length: A4: 300mm or 11' Effective writing width: 204mm Resolution: - Vertical: 8 dots/mm - Horizontal: 16 dots/mm |
Electrical | Internal noise: 20uV(p-p) max Input circuit: Floating input Isolated and defibrillation protected Input impedance: >10MQ Input range: > +/- 5mV Common Mode Rejection: >+100dB DC offset voltage: >+/- 300mV Time constant: 3.2 sec Patient Leakage current: <10uA Frequency response: 0.05 ~ 150Hz |
Signal Quality control | Disconnected lead detection |
Power | Power Supply: AC or built-in Battery (option) Power requirement: 100 – 240 Vac, 50/60Hz, 1.0 – Power consumption: 60w max |
Battery capacity | 1 hour of normal use (approximately 100 automatic printouts) |
Communication | PC connection with RS-232 interface and LAN |
Safety | Class 1, Type BF |
Conformity | CE, CSA |
Environment | Operating humidity: 30 – 85% Operating temperature: 10° ~ 40° C Atmospheric pressure: 70 ~ 106KPa |
Standard accessories | Power Cable – 1ea Patient Cable – 1ea Bulbs x 6, arm and leg clamps x 4 Chart Paper – 1ea Operation Manual – 1ea |
Options | Rechargeable Battery (ni-mh) Cart Hanger Bag PC s/w Limb electrode Chest electrode RS-232C null cable LAN cable (Ethernet-RJ-45) |
Handheld ECG Machines
Code – ECG80HH/S
Description – ECG PM80 Handheld & SPo2
Contec Ecg80a User Manual Transmission
Introduction | PM80 Portable ECG Monitor mainly faces families and individuals. It can record, analyze and display ECG waveform when consumers hearts are exceptional, catching exceptional ECG waveform, providing gist for diagnosing. The product isn't belong to medical device, only used to detect ECG momentarily |
Production characteristic | * 3.5-inch color TFT touch-screen * Adopting built-in electrode can observe single-lead ECG waveform fast * Continuous ECG monitoring mode * Achieving separate ECG,Oximeter collection and mixed collection * Analyse accurately, display intuitionistic and pellucid * Integrated case manage function, review, delete, storage case * TF mass memory medium * Carry through diversified settings according to user needs * Have divers form system tools, in order to provide more close service to user * Have mass rechargeable li-polymer battery |
Primary Technical Guide Line: | |
ECG | * Calibration Voltage: 1mV ± 5% * Standard Sensitivity: 10mm/mV ± 5% * Noise Level: ≤30μV * Common-mode rejection ratio: ≥ 60 dB * Scan rate: 25mm/s ± 5% * Sampling frequency: no less than 400point/s * Enduring polarization voltage: ±500mV |
Oximeter: Spo2: | * Measuring Range: 0~100% * Absolute error permit ± 2%, the metrical results display in the range with 70%~100% * Less than 70% is not defined. Pulse Rate: * Measuring range: 35bpm~250bpm * Error ± 2bpm or 2% which is greater |
Accessories | Sell in standard: * A user manual * 2GB T-Flash card * ECG Cable * disposable electrodes * High-quality bag * A power adapter(5V/1A) * A data line * A disk (PC software) Sell in addition: * An oximeter probe * bluetooth |
Physical identity | * Dimension: 131mm (L) × 74 mm(W) × 28mm (H) * Weight: About140g |
Code – ECG80AHH/PR
Description – ECG 80A Handheld & Printer
Introduction | This product is single channel,12 leads electrocardiograph, can be widely applied in ECG check-up under different circumstances such as in family ,hospital consultation, doctor's diagnosis, physical check-up,social medical organizations etc. it can implement real time continuous records of clear and exact single-channel ECG waveform using thermo sensitive printer at the same time. waveforms also can be freezed at any time. it has manual and automatic modes to be chosen and Chinese/English operation interface,it is easy to be used |
Features | * 2.7″ FSTN display shows the working status and ECG waveform. Check the waveform before printing to save record paper. * Output system:High-resolution thermal-array(8dots/mm),it needs not be adjusted.Recording frequency Response:Up to 150Hz. * The device can record exact single ECG waveform and remark. The mark includes:lead sign,ensitivity,paper speed,filter state. * Under automatic mode,just press the button once,it starts record procedure,which can enhance your work efficiency * The language of operation interface include( Chinese,English,French,Italian,Turkish,Espanol,Deutsch,Russia) * The keyboard's control is whole touch type,it's convenient to operate. * Classification:IEC class I,type CF defibrillator proof * This instrument can record 160 pieces of ECG waveform and 4 hours continually under the best DC state * The figure of whole device is elegancy and gliding * According to defendence degree of deleterious fluid, this device is belong to common device. * Digital signal processor for effective inhibition of AC,EMG and DFT,receive the better ECG waveform. * According to the working mode class, this device belongs to continuous operation equipment |
Technical specifications | * Normal work environment Running Environment temperature: +5℃~+35℃ Relative humidity: ≤80% Atmospheric pressure: 86kPa~106kPa |
* Store and Transportation Environment temperature: -10~55℃ Relative humidity: ≤95% Atmospheric pressure: 50kPa~106kPa | |
* Input way: Floating and defibrilation protection * Lead: Standard 12 leads * Patient leak current: <10μA * Sampling rate:1000Hz * A/D change:10 Bit * Frequency response: 0.05Hz~150Hz * Time constant: Time constant>3.2s * CMRR: >60dB, >100dB( With AC filter) * Enduring polarization voltage:±500mV * Noise level: ≤15μVp-p * EMG interference filter: 35Hz(-3dB) * AC filter:50Hz/60Hz(≥20dB) * Sensitivity choice: 5,10,20mm/mV, error:±5%.Standard sensitivity is 10mm/mV±0.2mm/mV * Recording way: Thermal printing system * Auto-record: according the the record format and auto-mode to set, auto leads-changing, auto measurement. * Manual record: according the record format to record, manual leads-changing. * Specification of recording paper:50mm(W) × 20mm(L)High-speed thermal paper * Paper speed: 25mm/s,50mm/s,error:±5% * Product safety type:IEC class I,type CF defibrillator proof * Size:190mm(L)*90mm(W)*40mm(H) * Net Weight:0.45kg * Power supply * Input: AC: 100-240V, 50/60Hz Output: DC: 9V DC: 7.4V, Lithium rechargeable battery | |
Accessories | ECG leads 1 set Limb electrode clamp 1 set Chest electrode 1 set Power connection 1 piece Recording paper 1 piece Power adapters 1 piece User manual 1 piece |
Option | ECG80A software, connect with the PC by USB , collect real-time data to the software to analyze and print the report, Certification CE, CCC, FDA |
Holter ECG Machines
Code – ECG9803HS
Description – ECG TLC9803 – 3 Channel Holter system
Introduction | TLC9803 Dynamic ECG Systems adapts 3-lead system defined by our company, can record continuously ECG waves for 24h, and analyses waves with PC software. It is applicable in hospital and community medical establishment |
Main features | * Quick and accurate analysis system. * The 3-lead synchro analysis, to find accurate, QRS search can be accurate and no distortion. * There are more than 10 templates as atrial premature beat module, ventricular premature beat module, long interval module, atrial flutter module, atrial fibrillation module etc. and multiplicate User-defined templates could almost identify every kind of pathologic waveforms. * Flexible analysis channel selection function, can choose any channel as the mainly analysis the channel. * Flexible atrial fibrillation analysis,so that physicians can use full,segmented automatic,manual analysis of atrial fibrillation,make the analysis more quickly and accurately. * Powerful pacemaker analysis, on the AAI,VVI,DDD etc. all pacemaker analysis. * Many pacing modules have been added. * Fast review analysis function, can be any period of time the review single lead or all leads electrocardiogram. * Analysis of heard rate variability with short-range 5 minutes and long-range 1 hour and 24 hours analysis of heart rate variability. * One-stop printing operation, report printing process is convenient and quick. * Perfect function of case management. * Advanced ST segment analysis and myocardial ischemia total load, can for the ST abnormal analysis according to the whole and event, make the doctor can comprehensive judgment myocardial ischemia. * Unique 'Sleep breath pause syndrome analysis' analysis can predict Sleep breath pause risk. * 'HRT' analysis can predict the risk of death in patients with myocardial infarction. * 'T Wave alternation' analysis is an important index to predict malignant arrhythmia and sudden cardiac death |
Recorder features | * With advanced design and technology, the recorder can work stably, dependably and durably. * Be provided with the capability of anti-jamming and aseismic. * Small volume with OLED screen. The resolution is 160*128. * Be provided with functions of waveform preview, record review and event marking. * Accurate record of the start time of the data sampled owing to the real time clock of itself. * Avoid damage owing to the repeating inserting and pulling out by using the inbuilt TF card to storage the data. * The maximum capability can be 2GB, so the original data can be saved perfectly by no compression. * The average review time of single case can be less than 40 seconds by using interface of USB 2.0. * Record waveform details inextenso by the design of high precision and sampling frequency. * Record the state of pacemaker exactly by higher sampling frequency. |
King root pcfasrers. ECG Gel and Paper
Code – ECGgel250ml
Description – ECG gel 250ml
Code – ECGgel5l
Description – ECG gel 5L
Code –
Description – ECG Electrodes spray 200ml
Code – ECGBM-PAP
Description – Paper for bestman
Code –
Description – Paper for contec 300G and 600G 110mm
Contec Ecg80a User Manual Pdf
Code –
Description – Paper for 800G
Code –
Description – Paper for contec 1200G 210mm
Contec Ecg80a User Manual
Code –
Description – Paper for ECG1112
Code – ECGC2000-PAP
Description – Paper for cardiocare
Code – ECGCW-PAP
Description – Paper for carewell machines